H₂S Analysers

  • Measurement specific to H₂S
    No interference from other components
  • Measurement range
    Fully configurable between 0-50ppb to 0-100%
  • Single point calibration
    Low operational costs No Zero drift
  • Auto Validation system
    Onboard calibration system management
  • Integrated dilution software
    Low cost & improved efficiency
  • Multi-streaming capability
    Will control up to 4 streams simultaneously
  • Optional On-board Webserver
    Complete open communication.
  • On-board Data logging & Diag. Functions
    Complete storage capabilities.
  • Modbus TCP/RS485
    Open communication protocols
  • Density compensation (ppm/w) (option)
    4-20 mA Real-Time density compensated
  • Dual-Range software (option)
    Dual ranges possibilities

APPLICATIONS:
With its wide-ranging ability to measure H₂S from % levels down to ppb levels, the HG500 range of H₂S pro-cess analyzers can be utilized in many process industries, including:
– Natural gas pipelines
– Reformer recycle gas
– Gas processing
– Offshore gas production
– Fuel gas monitoring
– Biogas

PRINCIPLE OF OPERATION
A reel of paper tape impregnated with lead acetate is exposed to the gaseous process sample in the sample chamber. Hydrogen sulfide (H₂S) in the process sample reacts with the lead acetate, after humidification, to form lead sulfide (PbS), a brown compound that stains the tape. The higher the concentration of H₂S is the faster the darkness of the stain is. A bi-directional fiber optic measures the darkening stain and the analyzer computes the concentration of H₂S.
Incremental measurements are made on the same spot until saturation occurs when the tape is advanced to a fresh portion of the tape. This avoids the need for frequent zero or span calibrations.

SPECIFICATIONS ANALYSER:
Measurement principleColorimetric (complies with ASTM D4045, D4084, D4323, D4468)
Typical ranges0-100 ppb/v, 0-1 ppm/v, 0-50 ppm/v, 0-1% Other ranges on request
KeypadAccessible through flameproof box using Touchsense™ technology
Repeatability± 1% full scale
Accuracy± 1% full scale
DriftNo zero drift
Output1 x 4-20mA per detection module; Modbus TCP/IP and RS485
Alarms1 x measurement alarm, 1 x instrument failure alarm. Other alarms available
Area classificationIECEx / ATEX approved, Ex d [ia] IIC T6
Ambient temperature limits-20°C to +55°C
Tape lifeUp to 90 days depending on the application.
Weather protectionIP66
Response time Auto validationDepends on the application but typically 10sec Optional
UTILITIES
Power85 / 250 VAC 50 / 60 Hz, 40 VA
Process sampleMini/Max pressure 0.5 – 4.0 barg,  Mini/Max flow rate 100 to 300 cc/min , Mini/Max  0°C – 80°C temp
Nitrogen or Inst. AirDry, pressure 3.0 – 10.0 BarG, flow 100 to 500 cc/min (models 502 & 503), optional for model 501
Detection box purgeOptional – 2 L/min (typical)
INSTALLATION
Process connections⅛” OD inlet, ¼” NPT female vent (to atmospheric vent)
Analyzer VentTo the atmosphere, no back pressure or vacuum allowed
SizeWeight 35 Kg approx., dimensions 378(w), 975(h), 235(d) mm

Options:
Total Sulphur
Density, Moisture, Temperature, Flow

MODELS:
Model 501 for low range (up to 80ppm)
Model 502 for mid-range (80 – 1000ppm)
Model 503 for high range (1000ppm – 100%)