IP.65 DETECTION MODULE INTRINSIC SAFE ATEX STANDARD
ELECTRONIC MODULE 19’’ RACK REMOTE INSTALLATION
TYPICAL APPLICATIONS
- Offshore Platforms Gas Pipeline
- Monitoring Sour Gas Treaters
- Storage Tanks
- Monitoring Amine Treaters
- Ammonia Plants
- Stack Gas Monitoring
- Ethylene/Propylene Plants
- Fuel Gas to Boilers
- Reformer Recycle Gas
SPECIAL FEATURES
ASTM D4080, D4084, D4323 compliance
software SIL2 certified
Interference-free (selective to H2S only)
Wide rangeability (50 PPB up to 600 PPM without dilution)
Fiber optic technology
Microprocessor electronics (PC 104)
Multiplexing capability (up to 4 detection modules)
Multistreaming capability (up to 4)
Very short response time (typically 20 s at 5 PPM)
No zero/span drifts
16 keys keypad TOUCHSENSE™ technology
PPB sensitivity
Dedicated failure alarms
1 analog output (4-20 mA) per detection module
OPERATING PRINCIPLE
Hydrogen sulfide reacts specifically in presence of lead acetate by forming lead sulfide (Pbs)
Pb (Ac)2 + H2S = Pbs + 2 ACOH
The NOVASULFTM HG 400 Series measures the speed of darkening resulting from the formation of lead sulfide on the tape by means of a fiber optical photodetector. At the beginning of each measurement cycle, the tape advances to a new blank portion (spot) of the tape. As soon as the H2S reacts on the tape, the speed of darkening measurement is done by comparison with the calibration curve stored in the instrument memory. Several measurements are done on the same spot, up to the saturation level.
When saturated, the tape advances for a new measurement cycle. During the tape advances, the last measurement is held in the instrument memory. Using this method no zero or span drifts can occur. Furthermore, measurements can be achieved even on already darkened (polluted) spots as far as it does not reach the saturation point.
By measuring every millisecond and averaging every second, the instrument response time is very fast even at very low concentrations. The H2S concentration is directly digitally displayed in the required units (PPB, PPM…).
Several analog outputs are available including process and instrument failure relay contacts.
AVAILABLE MODELS
MR 301: Rangeability from 0-100 PPB up to 0-600 PPM
Detection Module – Sizes : W 370 x H 450 x D 210mm – Weight : 10 Kg approx.
19’’ Electronic Module – Sizes : W 270 x H 177 x D 340mm – Weight : 5 Kg approx.
STANDARD SPECIFICATIONS
STANDARD SPECIFICATIONS | |
– Principle | Colorimetric. |
– Detector | Single photodetector acting as a measure and reference linked to a fiber optic cable. Tape illuminated by a focused LED via the same fiber-optic path. |
– Electronics | PC 104 type. Intel Celeron 400 MHz microprocessor. 256 Mb SDRAM embedded memory. 512 Mb compact Flash for the operating system, the application, the customer parameters, and the calibration curves storage. |
– Software | C++, Windows TM XPe based. |
– Range unit | PPB/V, PPM/V, PPB/W, PPM/W, mg/m3, mg/l – depending on the application. |
– Rangeability | 0-50 PPB up to 0-20% depending on the selected model. |
– Sensitivity | 2 % of the concerned range. |
– Response time | Between 20 s and 120 s, depending on the range. Full-scale deviation. (typically 20 s at 5 PPM) |
– Linearity | ± 2 % of calibration full scale. ± 3% below 10% of the scale |
– Reproducibility | ± 2 % of calibration full scale. ± 3% below 10% of scale |
– Accuracy | ± 2 % of calibration full scale. ± 3% below 10% of scale |
– Zero/span drift | None due to a single photodetector technique. |
– Multiplexing capability | Up to 4 detection modules. |
– Multistreaming capability | Up to 4. Using up to 4 detection modules (optional) with only one electronic module. |
– Process alarm | 1 per stream. Adjustable level. Potential free relay contacts 3A 230 VAC rated in N.O. or N.C. Relay coil normally energized or de-energized (programmable). |
– Instrument failure alarm | 1 per stream. Potential free relay contacts 3A 230VAC rated in N.O. or N.C. Relay coil normally energized. Dedicated alarms are available on the digital output (RS 485). |
– Analog output(s) | 1 as standard – up to 4 on option. 4-20 mA self-powered, galvanically isolated, 1000 ohms max, loop load. |
– Built-in keyboard | 16 keys, optical TOUCHSENSE™ technology. |
– Built-in display | Alphanumeric 4 lines, 20 characters each, backlighted. – H2S concentration. – Functional parameters |
– Power supply | 85 up to 264 VAC – 47 up to 440 Hz. 120 VDC to 370 VDC. |
– Power rating | 40 VA max. |
– Area classification | Detection Module : CE 0080 II 1 GD c Ex ia IIC T4 c Ex iaD 20 IP66 T135°C c Ex is op Ga IIC T4 ** ** if optic fiber modules |
– Area classification | Electronic Module: Safe area – 19 inches rack |
– Ambient temp. | – 20 °C to + 40°C |
– Sensing tape | Lead acetate impregnated cellulosic paper CHEMCOLOR™. 60m roll. (200 feet). |
– Tape life | Between 14 and 60 days depending on the range and application. |
– Storage life | 5 to 7 years, under the original sealed envelope. |
– RFI protection | Conform to EN 50270: 2006 (Product type 2) |
– Sample flow rate | 0.15 up to 0.30 l/min at 1.10 bara depending on the range and application. Flow alarm switches optional. |
– Sample temperature | 0°C up to + 40°C (gas phase). |
– Sample humidifier | 5 % acetic acid in distilled water, to optimize the chemical reaction on the tape. Consumption 5 to 10 ml per week depending on the sample nature. Low-level alarm optional. |
– Analyser vent | To atmosphere. NO BACK PRESSURE OR VACUUM ALLOWED, which would affect the measure. Vent compensation system optional. |
– Dilution systems | Above 600 PPM for HG 302 and HG 303. |
– Dilution gas | Nitrogen, 0.5 up to 5 L/min at 1.10 bara depending on the application. |
– Ambient working temp. | 0°C up to + 40°C – 2°C stability for optimum performances. |
– Storage temperature | Analyser : -15°C up to + 60°C Sensing tape : -10°C up to + 60°C Humidifying solution: 0°C up to + 40°C. |
– Relative humidity | 90 % max. non condensing. |
– Material | 316L Stainless steel, all material compatible with H2S. |
– Connections | 1/8 ” OD, 1/4” NPT Female |